Vantage Elan offers a wide variety of solutions to meet the demands of modern clinical environments such as a small installation footprint, 1.4m ultra-short magnet, Pianissimo™ noise reduction technology, Canon software and Atlas SPEEDER™ coils.
Non-contrast time-resolved flow can be visualized by using the free-breathing mASTAR sequence. Additionally, mASTAR flow series may be fused with static sequences in Canon Software Fusion post processing applications.
View Scan ParametersSequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
PORTAL mASTAR | 45x25 | 1.1x1.1 | 6 PHASES | |
RENAL CORONAL mASTAR | 36x25 | 0.7x0.7 | 6 PHASES | |
RENAL AXIAL mASTAR | 25x20 | 0.6x0.6 | 6 PHASES |
Large field-of-view, contrast enhanced MR Enterography performed with the Atlas Body SPEEDER™ and Octave Spine SPEEDER™ coils. T2, FASE T2, DWI, and dynamic sequences aids clinicians in visualization of pathology and intricate detailed anatomy.
View Scan ParametersSequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
COR T2 | 42x36 | 0.5x0.5 | FASE 2D | |
AX T2 | 36x36 | 0.6x0.6 | FASE 2D | |
AX DWI | 38x37 | 1.4x1.4 | B/W INVERSE COR MPR B/W INVERSE |
|
AX DWI | 38x37 | 1.4x1.4 | B/W INVERSE COR MPR B/W INVERSE |
|
COR DYN | 34x40 | 0.8x0.8 | FFE 3D |
The Vantage Elan system allows acquisition of MRCP study comfortably by using the flexibility of the Atlas Body SPEEDER™ coil while providing high image quality and reproducibility. 3D imaging post-processing can be easily performed on the Canon software console.
View Scan ParametersSequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
CORONAL 3D FASE | 35x25.6 | 0.3x0.3 | 3D MRCP MIP AND SVR |
|
CORONAL 3D FASE | 35x25.6 | 0.3x0.3 | 3D MRCP MIP AND SVR |
|
CORONAL T2 FASE FS | 36x32 | 0.6x0.6 | - | |
CORONAL T2 FASE FS | 36x32 | 0.6x0.6 | - | |
CORONAL T2 FASE | 36x32 | 0.6x0.6 | - | |
AXIAL FE DUAL | 30x38 | 0.7x0.7 | IN-PHASE / OUT-PHASE |
Abdominal MRI performed with the Atlas SPEEDER™ Body and Octave SPEEDER™ Spine. This case displays a wide range of Canon Medical Systems' fat saturation techniques as SPAIR, Polarity Altered Spectral and Spatial Selective Acquisition (PASTA), and Enhanced fat sat.
View Scan ParametersSequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
COR FSE T2 | 36x40 | 0.8x0.8 | Respiratory Gating | |
COR FSE T2 FS | 36x40 | 0.7x0.7 | Respiratory Gating FS-SPAIR |
|
AX FSE T2 | 36x40 | 0.8x0.8 | Respiratory Gating | |
AX FSE T2 FS | 36x40 | 0.8x0.8 | Respiratory Gating FS-SPAIR |
|
AX DIFFUSION | 36x38 | 1.4x1.4 | b=800 FS PASTA ISO DWI and ISO ADC |
|
AX DYNAMIC | 36x40 | 0.8x0.8 | - |
MRI of the female pelvis performed with the combination of the Atlas SPEEDER™ and Octave SPEEDER™ Spine coils. Visualization of pathology with a multiparametric approach can be achieved.
View Scan ParametersSequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
SAG T2 JET | 25x25 | 0.5x0.5 | - | |
AX T2 JET | 25x25 | 0.5x0.5 | - | |
COR T2 JET | 25X25 | 0.5x0.5 | - | |
DWI | 25X39 | 1.1x1.1 | Iso DWI | |
SAG DYN | 22x22 | 0.4x0.4 | - |
Multiparametric MRI of the prostate including dynamic and diffusion can be acquired with short scan times increasing patient comfort.
View Scan ParametersSequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
SAG FSE T2 | 25.4x28.7 | 0.5x0.5 | - | |
AX FSE T2 | 20x20 | 0.4x0.4 | T2+ | |
AX DIFFUSION | 25x37 | 0.9x0.9 | FS PASTA | |
ISO DWI | 25x37 | 0.9x0.9 | b=800 | |
ISO ADC | 25x37 | 0.9x0.9 | b=800 | |
AX DYNAMIC | 28x28 | 0.7x0.7 | FS-Enhance |
Subscribe to receive information on products.
© Canon Medical Systems, USA. All rights reserved.
Design and specifications subject to change without notice.