Designed to help you increase productivity and lower running costs, ensure patient comfort and deliver clinical confidence, Vantage Orian is the perfect answer to your 1.5 Tesla MRI business and clinical requirements.
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Abdomen MRI include DWI and T2 sequences
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Ax T2 FS Ax T2 |
30 x 35 30 x 35 |
0.7 x 0.7 0.7 x 0.7 |
Respiratory Gated | |
IsoDWI b= 800 IsoADC b=800 cDWI b=400 cDWI b=2000 |
23 x 35 | 1.3 x 1.3 | - |
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Abdomen MRI including Quick Star and DWI
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Cor FASE T2 | 34 x 36 | 0.6 x 0.6 | - | |
3D T1 | 30 x 35 | 0.7 x 0.7 | Free-breathing | |
3D T1 QS | 39 x 39 | 0.8 x 0.8 | Free-breathing | |
Ax FASE T2 | 35 x 35 | 0.5 x 0.5 | - | |
Iso.DWI b=400 cDWI b=800 IsoADC b=400 |
35 x 40 | 0.8 x 0.8 | - |
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Abdomen MRI including MultiBand Comparison and Quick Star
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
DWI Routine (left images) |
32 x 35 | 1.4 x 1.4 | IsoDWI, calculated b=800, IsoADC | |
DWI MultiBand (right images) |
32 x 35 | 1.4 x 1.4 | IsoDWI, calculated b=800, IsoADC | |
3D T1 (top images) |
36 x 36 | 0.7 x 0.7 | Free-breathing | |
3D T1 Quick Star (bottom images) |
36 x 36 | 0.6 x 0.6 | Free-breathing | |
Ax T2 FS | 30 x 35 | 0.8 x 0.8 | - | |
Ax T2 | 30 x 35 | 0.7 x 0.7 | - |
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Chest UTE (Ultra Short TE)
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Cor UTE | 42 x 42 | 1.0 x 10 | MPRs post processed on Canon software |
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Female pelvis MRI including JET and DWI sequences
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Ax T2 | 36 x 25 | 0.4 x 0.4 | - | |
Cor T2 | 38 x 25 | 0.4 x 0.4 | - | |
Sag T2 | 28 x 25 | 0.4 x 0.4 | Left images | |
Sag T2 JET | 25 x 25 | 0.5 x 0.5 | Right images | |
IsoDWI b=1000 IsoADC b=1000 cDWI b=400 |
32 x 38 | 0.8 x 0.8 | B/W inverted image created on Canon software | |
Ax 3D T1 | 28 x 28 | 0.5 x 0.5 | FS Enhanced | |
Sag 3D T1 | 28 x 28 | 0.5 x 0.5 | FS Enhanced |
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Prostate MRI DWI and T2 sequences
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Ax T2 | 20 x 20 | 0.4 x 0.4 | - | |
Cor T2 | 20 x 20 | 0.4 x 0.4 | - | |
Sag T2 | 20 x 20 | 0.4 x 0.4 | - | |
IsoDWI b=1000 IsoADC b=1000 |
20 x 20 | 0.9 x 0.9 | - |
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Renal MRI including Dixon, Quick Star, DWI and MRA
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Ax Dixon | 34 x 35.6 | 0.7 x 0.7 | FSE Dixon *(4 weightings: In-Phase, Out-Phase, Water, Fat) |
|
Ax Quick Star | 40 x 40 | 0.6 x 0.6 | Free-Breathing FS Enhanced |
|
IsoDWI b=800 IsoADC b=800 |
35 x 35 | 1.6 x 1.6 | - | |
Cor Time-SLIP | 35 x 35 | 0.7 x 0.7 | MIP |
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Renal Non-Contrast MRA
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Cor Time-SLIP | 38 x 31 | 0.6 x 0.6 | MIPs and MPRs post-processed on Canon software |
Coil:
Atlas SPEEDER™ Body and Atlas SPEEDER™ Spine Coils
Additional Information:
Renal Non-Contrast MRA
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Cor Time-SLIP | 38 x 28.1 | 0.5 x 0.5 | MIPs and SVR post-processed Canon software |
Coil:
Atlas SPEEDER™ Head/Neck, Body and Spine Coils
Additional Information:
Whole Body MRI including FSE Dixon and DWI
Sequence | FOV | Resolution | Other Parameters | Other Param |
---|---|---|---|---|
Cor T2 | 50.7 x 100.6 (4 Stations) |
1.0 x 1.0 | - | |
Cor T2 Fat Suppressed | 50.7 x 100.6 (4 Stations) |
1.0 x 1.0 | - | |
Cor T1 | 50.7 x 100.6 (4 Stations) |
1.0 x 1.0 | - | |
Cor DWI | 50.7 x 100.6 (4 Stations) |
1.0 x 1.0 | - |
Subscribe to receive information on products.
© Canon Medical Systems, USA. All rights reserved.
Design and specifications subject to change without notice.