Introducing the all-new Aquilion ONE / INSIGHT Edition. Built from the ground-up with our next-generation gantry and optics, the latest Deep Learning Reconstruction technology, and PIQE 10241.
1Option
The powerful combination of PIQE 1024* on the new Aquilion ONE / INSIGHT Edition and ONEBeat Cardiac scanning with ultra-fast 0.24 s rotation speed delivers high quality coronary CTA examinations for your patients while overcoming the challenges of visualizing small structures.
Super-resolution1 + low-contrast detectability + low-noise + low-dose.
Courtesy of Dr. M. Chen, NHLBI, National Institute of Health, USA
Scan Mode | Volume |
Collimation | 0.5 mm x 80 |
kVp | 120 |
mAs | SUREExposure 3D |
Reconstruction | PIQE 1024 Matrix |
CTDlvol | 5.7 mGy |
DLP | 68.3 mGy·cm |
Effective Dose* | 0.96 mSV |
* AAPM Report 96, k-factor 0.014
*Option
1PIQE is designed to fully utilize the maximum resolution of the detector
2Global Illumination is a purchasable option, available in combination Vitrea® Advanced Visualization
Improve Cardiac image quality without dose penalty using the powerful combination of PIQE 1024 Super Resolution2 DLR with the all-new Aquilion ONE / INSIGHT Edition CT scanner. Featuring ONEBeat cardiac capabilities with ultra-fast 0.24 s rotation speed and high 1400 mA tube limit that will deliver high-quality coronary CTA examinations for your patients.
Courtesy of Dr. M. Chen, NHLBI, National Institute of Health, USA
Scan Mode | Volume |
kVp | 120 |
mAs | SUREExposure 3D |
Reconstruction | PIQE 1024 Cardiac |
CTDlvol | 11.6 mGy |
DLP | 139 mGy·cm |
Effective Dose* | 1.9 mSv |
* AAPM Report 96, k-factor 0.014
1Option
2PIQE is designed to fully utilize the maximum resolution of the detector
Unleash the power of AI-trained PIQE 1024 super resolution1 on the new Aquilion ONE / INSIGHT Edition for super-resolution1 + low-contrast detectability + low-noise + low-dose.
Provide super resolution1 CT with the ultra-fast rotating, wide-area coverage of the redesigned PUREINSIGHT Detector, available on the all-new Aquilion ONE / INSIGHT Edition.
Courtesy of Dr. M. Chen, NHLBI, National Institute of Health, USA
Scan Mode | Ultra Helical |
Collimation | 0.5 mm x 80 |
kVp | 120 |
mAs | SUREExposure 3D |
Reconstruction | PIQE 1024 Cardiac |
CTDlvol | 4.3 mGy |
DLP | 51.4 mGy·cm |
Effective Dose* | 0.7 mSv |
* AAPM Report 96, k-factor 0.014
*Option
1PIQE is designed to fully utilize the maximum resolution of the detector
2Cardiac Analysis and Global Illumination are purchasable options, available in combination Vitrea® Advanced Visualization
Subscribe to receive information on products.
© Canon Medical Systems, USA. All rights reserved.
Design and specifications subject to change without notice.