Introducing the all-new Aquilion ONE / INSIGHT Edition. Built from the ground-up with our next-generation gantry and optics, the latest Deep Learning Reconstruction technology, and PIQE 10241.
1Option
PIQE 1024* Body overcomes the challenges of visualizing small structures and provides sharp borders between lesions without loss of low contrast resolution or additional radiation dose to the patient.
Courtesy of Fujita Health University, Japan
Scan Mode | kVp | mAs | Reconstruction |
---|---|---|---|
Ultra-Helical | 120 | SUREExposure | PIQE |
* Option
1 PIQE is designed to fully utilize the maximum resolution of the detector
Every second counts in the Emergency Department. This ED patient underwent a Chest/Abdomen/Pelvic CT Angiogram that was completed in only 2 seconds. The Aquilion ONE / INSIGHT Edition offers ultra-fast 0.24-second* rotation speed, wide-area 16 cm helical coverage, and a rapid 450 mm/s* table speed to ensure swift and more confident diagnoses for emergency department patients.
View Scan ParametersScan Mode | kVp | mAs | Reconstruction | CTDIvol | DLP | Effective Dose† |
---|---|---|---|---|---|---|
Ultra-Helical | 120 | SUREExposure | AiCE | 4.7 mGy | 362.9 mGy·cm | 5.2 mSv |
†AAPM Report 96, k-factor 0.0145
* Option
1 Global Illumination is a purchasable option, available in combination Vitrea® Advanced Visualization
The CoolNovus x-ray tube from the Aquilion ONE/INSIGHT Edition delivers low 70 kV scanning for better contrast visualization in vascular imaging.
Using low kVp settings during CT Angiography scans:
Scan Mode | kVp | mAs | Reconstruction | CTDIvol | DLP | Effective Dose† |
---|---|---|---|---|---|---|
Helical | 70 | SUREExposure | PIQE | 1.7 mGy | 221.2 mGy·cm | 3.2 mSv |
†AAPM Report 96, k-factor 0.0145
* Option
1 Optimization of contrast usage is only recommended within the dosing ranges that appear in approved iodinated contrast drug labeling
Bariatric patients presents certain challenges due to their habitus, including reduced image quality, longer scan times, and difficulties with positioning. The Aquilion ONE / INSIGHT Edition is equipped with technology essential to overcome these challenges and ensure accurate diagnosis, a wide 80 cm bore, high 695 lbs. weight capacity couch, and noise reducing AI-trained deep learning reconstructions.
View Scan ParametersScan Mode | kVp | mAs | Reconstruction | CTDIvol | DLP | Effective Dose† |
---|---|---|---|---|---|---|
Pre-Contrast Helical | 120 | SUREExposure | AiCE | 23.0 mGy | 745.3 mGy·cm | 10.4 mSv |
Post-Contrast Helical | 120 | SUREExposure | AiCE | 23.9 mGy | 775.9 mGy·cm | 10.8 mSv |
†AAPM Report 96, k-factor 0.014
* Option