Aquilion ONE GENESIS CT Scanner Benefits

Dose Reduction

Every Patient. Every Time.

Aquilion ONE GENESIS AIDR 3D Integrated

The industry's most comprehensive dose management controls include Adaptive Iterative Dose Reduction 3D (AIDR 3D Enhanced) technology and SUREkV, which automatically optimize dose for every procedure and make it possible to scan more dose-sensitive patients.

Request a Quote

Forward projected model-based Iterative Reconstruction SoluTion.

FIRST (MBIR*)

Forward projected model-based Iterative Reconstruction SoluTion

Following Canon Medical Systems' long standing philosophy for reducing dose, while maintaining clinical workflow, Canon Medical Systems' Aquilion ONE GENESIS Edition provides sharp image detail with a fully integrated MBIR solution.

FIRST MBIR Demo


  • Easy to use: integrated into Patient Registration, Acquisition and Reconstruction
  • Up to 82.4%** dose reduction with improved image quality
  • Applicable to all scan modes
  • Fast reconstruction times in parallel with AIDR 3D images
    • Volume scans (320 images) = Approx. 3 mins
    • Helical scans (500 images) = Approx. 6 min

*Model-based Iterative Reconstruction
*Available on Aquilion ONE ViSION and Aquilion ONE GENESIS
**As compared to FBP
FIRST Integrated FIRST Integrated
FIRST Integrated FIRST Integrated

FIRST (MBIR)1 LCD

Help Clinicians Possibly Diagnose Early Stroke Sooner

In the United States stroke symptoms account for up to 3.7 million visits to hospitals and the Emergency Departments. Stroke is a leading cause of death in the United States, killing 130,000 American each year.2 FIRST Low Contrast Detectability (LCD) has the ability to improve low contrast detectability in a routine non-contrast brain scan by up to 101%.3


1 Model-based Iterative Reconstruction

2 Source: CDC, NCHS. Underlying Cause of Death 1999-2013 on CDC WONDER Online Database, released 2015. Data are from the Multiple Cause of Death Files, 1999-2013, as compiled from data provided by the 57 vital statistics jurisdictions through the Vital Statistics Cooperative Program. Accessed Feb. 3, 2015.

3 Based on the detectability index performance metric, a measure of signal to noise that takes into account the magnitude and texture of both the signal and the noise for a given LCD task. FIRST Brain LCD mode.

FIRST (MBIR*) LCD

Routine Non-contrast Brain

FIRST (MBIR*) LCD

2nd Recon using FIRST Low Contrast Detectability

FIRST (MBIR*) LCD

DWI

FIRST (MBIR*) LCD

MR Perfusion

FIRST (MBIR), Brain CTA

FIRST (MBIR) CTA has been shown to improve high contrast spatial resolution while lowering radiation dose.

Brain CTA

Without FIRST

Brain CTA

FIRST

Aquilion CT AIDR 3D Integrated

Adaptive Iterative Dose Reduction integrated into

SUREExposure3D — AIDR 3D

AIDR 3D has been developed as the next step in the evolution of noise reduction technology. This iterative algorithm removes noise in the raw and image data space, by analyzing and processing the data repeatedly.

Learn More About AIDR 3D

Short bore wide detector CT.

Patient Centric Design

  • A unique flared gantry providing a calming, wide-open space for a better patient experience
  • Improved access to your patients from the front and rear of the gantry
  • Providing safer care during trauma and interventional procedures
  • 63% shorter bore*

*Compared to competitive systems

Claustrophobic tunnel design

Claustrophobic tunnel design

Patient-friendly open flared design

Patient-friendly open flared design

Aquilion ONE CT: Less Time. Less Radiation.*

Pediatric Patient Benefits

About seven million CT scans are performed on children in the US annually**, and the majority of those children are under the age of 5.

Canon Medical Systems is doing its part in a way that may improve diagnosis time, reduce radiation dose and the potential to eliminate or reduce patient sedation with its Aquilion® ONE dynamic volume CT system — all while producing quality images.

Additionally, Canon Medical Systems has joined an industry-wide campaign to develop best practices to image children safely.

View Clinical Gallery


*Eric Barnes, "320-row CT cuts pediatric radiation dose versus 64-slice imaging," AuntMinnie.com, April 30, 2012.

**Mettler FA, Wiest PW, Locken JA et al. 2000, CT scanning: patterns of use and dose. J Radiol Prot. 20:353-359.

Aquilion CT Pediatric Patient Benefits

Increase lines of care with unique bariatric-friendly features.

Bariatric Patients Benefits

Obesity in the U.S. has steadily increased over the past 20 years with roughly 36% of all adults and 17% of all children and adolescents aged 2-19 years currently in this category.*

Aquilion ONE GENESIS CT Bariatric Benefits

Aquilion ONE Family of scanners meet the imaging needs for this population with:

  • 78 cm gantry opening
  • 8.4 cm of lateral movement with Tech Assist Lateral Slide**
  • Optional 660 lbs couch capacity
  • Flare gantry design to help reduce claustrophobia

*Source: www.ced.gov/obesity/data/facts.html
**Optional

A simple solution to position patients quickly and efficiently.

Tech Assist Lateral Slide*

Aquilion ONE CT Tech Assist Lateral Slide

8.4 cm of lateral table movement

  • Assist technologist in positioning and moving patient
  • Center patient in CT bore, improved mA modulation (dose) and image resolution

*Optional

Tech Assist Demo

Automated technique for kV selection

SUREkV

Aquilion ONE CT SURE kV
  • Integrated and easy to use radiation dose management
  • Automated kV selection based on patient size, SUREExposure settings and clinical task
  • Clinically targeted kV selections of: 80, 100, 120, 135