Aquilion ONE GENESIS SP CT Scanner Technology
AiCE

Deep Learning Reconstruction

See through the noise

The Advanced intelligent Clear-IQ Engine (AiCE), a revoluntary approach to CT reconstruction, uses Deep Learning to distinguish true signal from noise to deliver sharp, clear and distinct images at speed. Trained using vast amounts of high-quality image data, AiCE provides enhanced anatomical resolution across the whole body¹ including brain, lung, cardiac and musculoskeletal systems.

Learn more about AiCE

Aquilion ONE PRISM and AiCE

AiCE deep learning reconstruction images feature:

  • Our best low-contrast resolution, ever ¹,³
  • Dose neutral industry-leading ultra-high resolution²
  • Improved low-contrast detectability, noise and spatial resolution relative to hybrid iterative reconstruction
  • Image noise texture more similar to FBP compared to MBIR reconstruction³
  • Fast reconstruction
  • Easy workflow

¹1.5mm @ 0.3%, 22 mGy
²Aquilion Precision, Dose neutral between Ultra-high resolution mode with AiCE and normal resolution mode with hybrid iterative reconstruction
³Aquilion ONE / GENESIS SP

Enables multiple specialized studies within a single scan.

Variable Helical Pitch with three phases (vHP3)¹

vHP 3-Phase¹ allows three scans to be performed in a single acquisition, seamlessly transitioning between scan parameters optimized for each body region. vHP 3-Phase has potential for less contrast media and lower radiation dose by providing the flexibility to seamlessly transition:

  • Between ECG Gating on and off during a cardiac scan
  • Between dose and image quality during a CAP scan
  • Between fast and detailed pitch during a trauma scan

¹Available on Aquilion ONE / GENESIS SP, Aquilion Prime SP, Aquilion Lightning 80 and Aquilion ONE / PRISM Edition.

Wide, open and low, put your patients at ease

Patient Centric Design

  • 78 cm gantry bore
  • 47 cm couch width
  • 2000 mm scan range
  • 33 cm minimum couch top height, flexible table height for all age groups and the physically challenged
  • 600 lbs capacity couch
  • Tech Assist Lateral Slide option allows you to move the table 8.4 cm from side to side
Patient Centric Design

A couch designed for patient and technologist safety.

Tech Assist Lateral Slide¹

Advanced Couch Design¹ improves safety and comfort by providing a tool to mechanically move the patient to the correct position with the push of a button. Tech Assist Lateral Slide helps reduce the risk of injury to the patient and the technologist.

Tech Assist Demo

¹Optional

Tech Assist Lateral Slide

Once on the table, perfect positioning—no push, no pull.

Helps reduce rescans in time critical situations.

SUREPosition¹

  • Accurately center and position the patient by scan plan GUI
    • Up-Down
    • Left-Right (option with Tech Assist Lateral Slide)
  • Provides the ability to always perform iso-center scanning for best IQ, without re-centering and re-scanning the patient
  • System generates new (virtual) scanogram—never repeat scanogram
SUREPosition Demo

¹Available on Aquilion ONE / GENESIS SP, Aquilion Prime SP, Aquilion Lightning 80 and Aquilion ONE / PRISM Edition.

SUREPosition

Economize on space, not on performance.

Compact Design

  • Smaller, lighter and requires less power than other premium CT systems
  • Designed for an installation space of just 19 m2 (204 sq ft)¹
  • Can be installed into most existing CT rooms, avoiding costly renovations
204 square ft Installation Space, 125 kVA Power Capacity, 5,159 lb Gantry Weight

¹With small couch

Sleep mode

Power Save Mode Improvements

  • System gantry and table
  • Monitors
  • i-Station
Aquilion ONE PRISM Power Save Mode
Aquilion ONE PRISM Power Save Mode