From fast patient throughput to robust detailed scans and complete diagnostic capabilities, the Cartesion Prime SP AI-assisted digital hybrid PET-CT with superb TOF resolution is the system of choice for all.
Premium CT and PET features standard in all Cartesion Prime SP systems including the mobile configurations.
Scanner | Mode | Dose Reduction | Range | CTDIvol | DLP | Effective Dose | K factor1 |
---|---|---|---|---|---|---|---|
Aquilion Prime SP | Gated Helical | AiCE | 110.0 mm | 10.8 mGy | 158.5 mGy·cm | 2.2 mSv | 0.014 |
1AAPM Report 96.
Global Illumination in combination with Vitrea® Advanced Visualization.
Clinical results are the experience of the facility. Results may vary due to clinical setting, patient presentation and other factors.
Scanner | Aquilion Prime SP |
Mode | Helical |
Dose Reduction | AiCE |
Range | 392.0 mm |
CTDIvol | 0.4 mGy |
DLP | 15.7 mGy·cm |
Effective Dose | 0.2 mSv |
K factor1 | 0.014 |
1AAPM Report 96.
Clinical results are the experience of the facility. Results may vary due to clinical setting, patient presentation and other factors.
Scanner | Aquilion Prime SP |
Mode | Helical |
Collimation | 0.5 x 40 |
Dose Reduction | AiCE |
kVp | 120 |
mAs | 240 |
Rotation Time | 0.75 sec |
Range | 140 mm |
CTDIvol | 57 mGy |
DLP | 915.8 mGy·cm |
K factor1 | 0.0021 |
1AAPM Report 96.
Clinical results are the experience of the facility. Results may vary due to clinical setting, patient presentation and other factors.
Scanner | Mode | Dose Reduction | Range | CTDIvol | DLP | Effective Dose | K factor1 |
---|---|---|---|---|---|---|---|
Aquilion Prime SP | Ultra-Helical | AiCE | 222.0 mm | 3.3 mGy | 86.4 mGy·cm | N/A | N/A |
1AAPM Report 96.
Clinical results are the experience of the facility. Results may vary due to clinical setting, patient presentation and other factors.
Scanner | Mode | Collimation | Dose Reduction | kVp | mAs | Range | CTDIvol | DLP | Effective Dose | K factor1 |
---|---|---|---|---|---|---|---|---|---|---|
Aquilion Prime SP | Ultra-Helical | 0.5 x 80 | AiCE | 120 | SUREExposure | 421.0 mm | 9.2 mGy | 431.4 mGy·cm | 6.4 mSv | 0.015 |
1AAPM Report 96.
Clinical results are the experience of the facility. Results may vary due to clinical setting, patient presentation and other factors.
Scanner | Mode | Dose Reduction | Range | CTDIvol | DLP | Effective Dose | K factor1 |
---|---|---|---|---|---|---|---|
Aquilion Prime SP | Ultra-Helical | AiCE | 1490.0 mm | 2.6 mGy | 406.7 mGy·cm | N/A | N/A |
1AAPM Report 96.
Clinical results are the experience of the facility. Results may vary due to clinical setting, patient presentation and other factors.
Subscribe to receive information on products.
© Canon Medical Systems, USA. All rights reserved.
Design and specifications subject to change without notice.