CLEAR Motion

CLEAR Motion

Powered by Altivity

Clearer with CLEAR Motion1,2

Powered by Altivity

Deep Learning Reconstruction (DLR) that reduces motion artifacts, improving image clarity, and diagnostic confidence. Combine motion compensation with Super Resolution3 PIQE1 1024 for sharp anatomical detail, without compromising on image noise or dose.

* Effective temporal resolution of 15.8 ms - Based on mathematical simulation. Data available upon request. Results may vary in clinical applications.
1 Option.
2 CLEAR Motion is available for Cardiac and Lung on the Aquilion ONE.
3 PIQE is designed to fully utilize the maximum resolution of the detector.

Clearer with Motion Correction

CLEAR Motion1, 2

Powered by Altivity

A raw data-based integrated Deep Learning Reconstruction (DLR) algorithm with a seamless workflow for cardiac and lung imaging.

  • Compatible with Super Resolution3 PIQE1 1024 DLR, and AiCE DLR for integrated motion correction, noise reduction, and low dose.
Clear Motion Chart
CLEAR Motion

CLEAR Motion OFF1, 2

CLEAR Motion ON1, 2

* Effective temporal resolution of 15.8 ms - Based on mathematical simulation. Data available upon request. Results may vary in clinical applications.
1 Option.
2 CLEAR Motion is available for Cardiac and Lung on the Aquilion ONE.
3 PIQE is designed to fully utilize the maximum resolution of the detector.
Courtesy of Dr. Chen, National Institute of Health, USA.

Clarity with CLEAR Motion1,2

Powered by Altivity

Fully automated motion compensation, raw data based CLEAR Motion1, 2 combined with Super Resolution3 PIQE1 1024 for ONE-Beat4 cardiac imaging.

CLEAR Motion: ON vs OFF

1 Option.
 2 CLEAR Motion is available for Cardiac and Lung on the Aquilion ONE.
 3 PIQE is designed to fully utilize the maximum resolution of the detector.
4 Prospective gating scan mode available on the Aquilion Serve SP, Aquilion Exceed LB, and the Aquilion ONE family of scanners.
The clinical results, performance and views described are the experience of the clinicians. Results may vary due to clinical setting, patient presentation and other factors.
*Courtesy Fujita Health University, Japan.

Cardiac Motion Compensation with CLEAR Motion1, 2

Powered by Altivity

Fully automated motion compensation for clearer cardiac imaging.

Coronary CTA with high heart rate of 175 BPM* with PIQE 1024 and CLEAR Motion.1, 2

Cardiac Motion Compensation with CLEAR Motion

1 Option.
2 CLEAR Motion is available for Cardiac and Lung on the Aquilion ONE.
3 Global Illumination is available with Vitrea® Advanced Visualization.
4 Perivascular Analysis is available with Vitrea® Advanced Visualization.
The clinical results, performance and views described are the experience of the clinicians. Results may vary due to clinical setting, patient presentation and other factors.
*Courtesy Prof. Roy and Prof. Ohana, University Hospital of Strasbourg, France.