Oncology Solutions: Imaging

Imaging | Computed Tomography

CT innovations designed for accurate, comfortable oncology imaging with simplified workflow, high spatial resolution and automated dose reduction capabilities.

Aquilion Precision

Precision in Every Detail

The world's first Ultra-High Resolution CT (UHR CT) capable of resolving anatomy as small as 150 microns, providing CT image quality with resolution typically seen only in cath labs.

Overview Video

Aquilion Precision

ULTRA High Resolution CT

NEW Technologies:

  • UHR Detector
  • UHR DAS
  • UHR Tube
  • UHR Gantry
  • UHR Reconstruction

Learn More

0.25 mm detector

150 micron

Spatial Resolution

50 lp/cm at 0% MTF

Reference only

Aquilion Precision UHR CT

1024 x 1024 Matrix
Aquilion Precision UHR CT

New UHR Reconstruction Matrix

512 x 512
Conventional CT

512 x 512
Conventional CT

1024 x 1024
UHR CT

1024 x 1024
UHR CT

Clinical Examples

Lung 1

Lung
Lung

SHR / 0.25 mm
Courtesy of Kyorin University, Japan

Lung 2

Lung
Lung

HR / 0.5 mm
Courtesy of Prof. Prokop RadboudUMC, Nijmegen, the Netherlands

Can New Imaging Technologies Improve Patient Outcomes?

Can UHR CT Improve Outcomes with Better Detection, Diagnosis and Staging of Pancreatic and Biliary Cancer

Miyuki Sone, M.D.
National Cancer Center Hospital,
Tokyo, Japan

CME Webinar

Miyuki Sone, MD

Aquilion Prime SP

Oncology care with streamlined workflow

Built with premium technology migrated straight from our high-end CT, Aquilion Prime SP empowers your facility to handle all patients from pediatric to bariatric, while providing all staff with a fast and efficient solution to make their work easy.

System Highlights:

  • Up to 4 cm z-axis coverage
  • 0.5 mm × 80 PUREViSION detector row
  • 0.35 sec rotation

Overview Video

Aquilion Prime SP CT

PUREViSION Optics

An optimized beam spectrum based on PUREViSION Optics results in a better balance between image quality and dose.

Aquilion PRIME SP with PUREViSION Optics transforms routine imaging to new levels of image detail, resolution and dose.

PUREViSION Optics
PUREViSION Optics
PUREViSION Optics

vHP3*—Variable Helical Parameters

Overall faster scan times make vHP3 compliant to the needs of the patient. A single series reconstruction enables several studies to be interpreted simultaneously for faster reading.

  • May decrease radiation dose to the patient
  • May decrease the amount of IV contrast needed
  • May improve the workflow for complex clinical exams

*Option

Optimal Image Quality

Optimal Image Quality

Easy Patient Positioning

Aquilion Prime SP's accessible gantry and couch were designed with every patient in mind providing comfort for bariatric and elderly cancer patients.

Easy Patient Positioning
Easy Patient Positioning

*Option

Aquilion Prime SP's accessible gantry design and powerful advanced imaging applications deliver an ideal oncology solution to assist clinicians with visualization, staging and treatment planning.

Adaptive Iterative Dose Reduction 3D

Adaptive Iterative Dose Reduction 3D

Single Energy Metal Artifact Reduction (SEMAR)

Single Energy Metal Artifact Reduction (SEMAR)

SURESubtraction unique Differential Iodine Enhancement

SURESubtraction unique Differential Iodine Enhancement

*Optional

Aquilion ONE GENESIS Edition

Transforming CT and Oncology care

Intensive clinically focused research and technological developments have culminated in a CT system capable of reduced radiation dose requirements and simplified workflow for tumor visualization and assessment.

System Highlights:

  • Up to 16 cm z-axis coverage
  • 0.5 mm × 320 PUREViSION detector row
  • 0.275 sec rotation
Aquilion ONE GENESIS Edition
Aquilion ONE GENESIS

Volume Perfusion Liver*

Tumor assessment with Whole Organ perfusion

Liver perfusion post chemo-embolization of Hepatocellular carcinoma. The ability to evaluate tumor response or anti-angiogenesis could make CT body perfusion a valuable clinical tool. 16 cm of z-axis coverage are key to accurately measuring whole organ perfusion.

Liver Perfusion Protocol: DLP = 720.8 mGy.cm, Effective dose = 10.81 mSv (k = 0.015)


*CT Volume perfusion only available with Aquilion ONE

Aquilion ONE GENESIS: Volume Perfusion Liver
Aquilion ONE GENESIS

SURESubtraction Body

Outstanding lesion visualization and assessment

  • Clinical indication
    • Assessment of tumors, lymph nodes, vascular lesions
    • Infarcts, ischemia
  • Iodine mapping
    • Blood flow mapping
    • Visualize local perfusion differences
    • Display local iodine concentration
    • Visualize contrast enhancement
  • Differential enhancement maps
    • "Pure" arterial and Venous maps

Courtesy Dr. Kon Bradford Teaching Hospital, UK

Aquilion ONE GENESIS: Unique Differential Iodine Mapping Enhancement Phases

Unique Differential Iodine Mapping Enhancement Phases

Expert Tools

CT Expert Tools: Lung

Lung


Applications

CT Lung Analysis
CT Lung Screening

CT Expert Tools: Colon

Colon


Applications

CT Colon Analysis

CT Expert Tools: Liver

Liver


Applications

CT Liver Analysis**

CT Expert Tools: Body

Body


Applications

CT Body Perfusion 4D* **


* CT Volume perfusion only available with Aquilion ONE
** Available on Vital

Imaging | PET/CT

Celesteion™ PUREViSION Edition PET/CT delivers Lesion metabolic assessment with precision and comfort for confident diagnosis.

PET


  • 88 cm PET bore
  • 394 ps typical Time-of-Flight
  • 19.6 cm axial field-of-view
  • 4 mm x 4 mm crystals

CT


  • 90 cm CT bore
  • 70 cm true FOV / 85 cm EFOV
  • PUREViSION 0.5mm x 16 detector
  • 32 mm coverage
  • 32 slice coneXact reconstruction
  • AIDR 3D dose reduction
  • SEMAR, Metallic artifact reduction
Celesteion PET/CT
Celesteion

Specifically Designed with the Patient in Mind

Celesteion delivers the largest PET/CT Bore and FOV enhancing patient comfort and care, without compromising quality.

70 cm True Field of View

With oncology patients, accuracy is everything. To meet this need, Celesteion offers a true 70 cm PET and CT field of view (FOV). This allows clinicians to overcome the challenges of a small 50 cm FOV, delivering unique access to help improve image quality and treatment planning.

90 cm Wide CT Bore

Celesteion’s wide bore is built for maximum patient positioning, comfort and peace of mind. The industry-leading 90 cm CT bore and 88 cm PET bore enhances your flexibility and workflow efficiency. By making patients feel more at ease, clinicians can have more confidence in their images and diagnoses.

SUREFLiGHT Reconstruction Technology

Time of flight (TOF) and point spread function (PSF) technology for improved uniformity across the FOV and fast reconstruction.

Celesteion PUREViSION edition with TOF and PSF reconstruction can improve image resolution.

  • 394 ps typical TOF
  • PSF reconstruction
  • Optimal speed and image resolution
  • Improved lesion visualization
  • Improved lesion localization
Time of flight Time of flight
Point spread function Point spread function

Imaging | Magnetic Resonance

MRI solutions that provide optimized image quality and workflow to help you deliver efficient, effective and comfortable care to your oncology patients.

Vantage Galan™ 3T / XGO Edition

Lesion Visualization with Optimized Image Quality and Patient Comfort

Get streamlined workflow, high-quality images and maximum patient comfort with Canon Medical Systems' Vantage Galan™ 3T MR system. The system was designed to meet the needs of you and your patients, giving you the tools you need to provide better patient care without compromising the patient experience.

View Brochure Overview Video

Vantage Galan 3T / XGO Edition

Unique acoustic noise reduction suites.

Pianissimo Zen¹


*99% reduction by unit of Loudness level "dB" and 97% reduction by unit of perceived loudness "Sone"

¹ Optional

Pianissimo Zen Chart

Vantage Galan 3T / XGO Edition*

With the new high performance Saturn X Gradient

Specifications/Features:

  • 45 mT/m Amplitude
  • 200 T/m/s Slew Rate
  • Advanced gradient design
    • High-Pressure Gradient Molding
    • Gradient Triple-Cooling

*Optional

Saturn X Gradient

Vantage Galan 3T / XGO Edition*

PUREGradient

Digital Gradient Waveform Control for gradient performance optimization.

  • 23% shorter TE
  • Up to 30% increase in SNR for Brain DWI
  • Up to 51% increase in liver DWI
  • Up to 110% increase in b-value at a fixed TE in DWI

*Optional

Increased SNR without increasing b-value

Increased SNR without increasing b-value

Standard Acquisition

Standard Acquisition

Higher diffusion weighting without increasing TE

Higher diffusion weighting without increasing TE

Vantage Galan 3T / XGO Edition*

PUREGradient with PURERF Technologies

PURERF technologies maximize the RF transmission efficiency for SNR improvements leading to optimal image quality.

Learn More

PURERF Technologies

Tumor Assessment

Post-Processing & 3D Visualization Applications

Image processing software solutions feature both viewing and analysis capabilities providing information about tumor volume, cellularity (DWI), aggressiveness (DCE), and perfusion (DSC/IVIM).

Tumor Assessment: Brain

Brain


Applications

  • Lesion Analysis*
  • Longitudinal analysis*
  • Brain Perfusion*
  • IVIM—Intravoxel Incoherent Motion*
Olea Medical

*Optional, designed and manufactured by Olea Medical

Tumor Assessment: Head & Neck

Head & Neck


Applications

  • Multi-Parametric Analysis*
Tumor Assessment: Women's Health

Women's Health


Applications

  • Breast MR
  • BI-RADS Reporting Tools*
  • Breast Tumor Follow-Up*
Tumor Assessment: Men's Health

Men's Health


Applications

  • Computed DWI (cDWI) Maps
  • Multi-Parametric Analysis
  • PI-RADS Reporting Tools*
  • IVIM—Intravoxel Incoherent Motion*
Lesion Analysis

Lesion Analysis

Longitudinal Analysis

Longitudinal Analysis

IVIM - Intravoxel Incoherent Motion

IVIM—Intravoxel Incoherent Motion
Quantitative separation of diffusion and perfusion from multi b-value DWI

Prostate Cancer - Multi-Parametric Analysis

Prostate Cancer—Multi-Parametric Analysis
PI-RADS Reporting Tools

  • Characterization
  • Localization
  • Grading/Staging
Breast Cancer

Breast Cancer
BI-RADS Reporting Tools

Imaging | Ultrasound

Intuitive. Intelligent. Innovative.

Aplio i-series

Crystal-clear images and comprehensive expert tools for outstanding clinical precision and departmental productivity.

Innovative System Architecture:

  • iBeam Forming
  • Intelligent Dynamic Micro-Slice
  • Multiplexing Architecture
  • Transducer Technology

Learn More

Aplio i-series

Comprehensive Experts Tools

Superb Micro-Vascular Imaging (SMI)

Superb Micro-Vascular Imaging (SMI)* offers enhanced microvascular flow visualization to help clinicians with confident diagnosis.

MicroPure

MicroPure improves visualization of microcalcification in breast tissue.

Precision Imaging

Precision Imaging offers better border definition and clarity of structures for confident diagnosis.

Contrast Enhanced Ultrasound Suite (CEUS)

Contrast Enhanced Ultrasound Suite (CEUS) Contrast-enhanced ultrasound allows for assessment of liver lesions enabling clinicians to utilize CEUS LI-RADS® categorization.

Elastography Suite

Shear Wave Elastography* for quantitative assessment of tissue stiffness and Shear Wave Dispersion* for assessment of dispersion slope which is a property related to tissue viscosity leading to more confident diagnosis.

Quad View

Quad View* allows you to view live ultrasound images from multiple imaging modes. This concise quad display can show live ultrasound images fused with volume data from a second modality to assist in identifying lesions more confidently.


*Availability dependent on system

2D and 3D* Cardiac Wall Motion Tracking

Novel solution for accurate pre- and post- therapy cardiac function assessment

Evaluate cardiac function during/before treatment. This appears to be increasingly important prior, during, and after cancer treatments to monitor patients' overall cardiac health status.

Aplio’s advanced Wall Motion Tracking technology provides immediate visual and quantitative access to global and regional myocardial wall motion dynamics in 2D and 3D, on both live and previously stored images.


*Availability dependent on system