Oncology Solutions: Image Guided Treatment Delivery

Oncology Solutions

Image Guided Treatment Delivery

Image Guided Treatment Delivery | Interventional Oncology

Sophisticated Interventional Oncology suites that can help you prioritize safety with maximum precision and efficiency.

Infinix-i 4D CT

True CT imaging prior, during, and after the interventional procedures

Enhance your treatment delivery and workflow

Canon Medical Systems’ Infinix-i 4D CT seamlessly integrates the interventional lab and CT scanner for a paradigm shift in interventional workflow. The combined room can help you expand your treatment capabilities and is ideal for a variety of interventional oncology procedures, including:

  • Transarterial Embolization (TAE) and Chemoembolization (TACE)
  • Selective internal radiation therapy (SIRT)
  • Portal Vein embolization
  • Ablations (RFA, Microwave, Irreversible electroporation)

View White Papers View Clinical Gallery

Real CT imaging available on demand may help you to:

  • Improve visualization and device manipulation
  • Offer anatomical and functional information
  • Eliminate patient transfer
  • Confirm procedural goal

As a result Infinix-i 4D CT may help you to:

  • Improve workflow
  • Increase efficiency1,2,3,4
  • Reduce time-to and time-of procedure
  • Increase patient safety
  • Reduce costs
Infinix-i 4D CT

Volume Perfusion Liver*

Tumor assessment with Whole Organ perfusion

Liver perfusion post chemoembolization of Hepatocellular carcinoma. The ability to evaluate tumor response or anti-angiogenesis could make CT body perfusion a valuable clinical tool. 16 cm of z-axis coverage are key to accurately measuring whole organ perfusion.

Liver Perfusion Protocol: DLP = 720.8 mGy.cm, Effective dose = 10.81 mSv (k = 0.015)


*CT Volume perfusion only available with Aquilion ONE ViSION Edition

Infinix-i 4D CT: Volume Perfusion Liver

Tumor Assessment Applications

Tumor Assessment Applications: Tumor & Vessels

Tumor & Vessels


Applications

Multi-Modality Fusion

Tumor Assessment Applications: Liver

Liver


Applications

CT Liver Analysis**

Tumor Assessment Applications: Body

Body


Applications

CT Body Perfusion 4D* **


* CT Volume perfusion only available with Aquilion ONE
** Available on Vital

David Hays, MD & Farah Gillen Irani, MD

CME Webinar: Image Guided Interventional Radiology Procedures Using a Combined Angiography CT System

David Hays, MD & Farah Gillen Irani, MD

CME Webinar
Junsung Choi, M.D.

CME Webinar: Improving Oncologic Outcomes Using a Unique 4DCT Solution

Junsung Choi, MD

CME Webinar
Infinix-i 4DCT Aquilion One ViSION Edition Live Case

Infinix-i 4DCT Aquilion One ViSION Edition Live Case:

Transarterial Chemoembolization (TACE) of the Liver

Watch Video
David Hays, MD

True CT Imaging Prior, During and After the Interventional Procedures in One Integrated Interventional Lab/CT Solution

David Hays, MD

Infinix-i Experience
Craig Comish

Infinix-i 4D CT Aquilion ONE ViSION Optimizes CARTI Cancer Center's Clinical Capabilities and Throughput

Craig Comish

Infinix-i Experience

Infinix-i Sky +

Image Without Limits

The C-arm revolution has arrived. Infinix™-i Sky + delivers unprecedented flexibility. Packed with advanced features in one comprehensive system, the sky’s the limit when it comes to complete coverage.

  • Features a double sliding C-arm and 12x16 flat panel
  • Imaging soars to even greater heights with an innovative C-arm flip, lateral flexibility, speed, and full body 3D imaging capability
  • Infinix-i Sky + offers revolutionary ImagingRite technology to generate a 3D image anytime, anywhere
  • Our DoseRite technology offers industry-leading dose management tools designed to help clinicians minimize patient X-ray exposure while maintaining optimum image quality

Clinical Gallery Clinical Brochure

Infinix-i Sky +

210 Degrees of Coverage

3D DA and 3D DSA can be performed from either side of the patient with the C-arm traveling 210 degrees at 80 degrees/sec providing the option for very fast acquisitions with high image quality.

Image Guided Treatment Delivery | CT Fluoro

Perform more efficient CT interventional procedures.

Volumetric CT Fluoro*

Axial, coronal, sagittal and oblique reference are used for optimal interventional guidance plan.


*Available on Aquilion ONE GENESIS, Aquilion ONE ViSION and Aquilion PRME

Volumetric CT Fluoro

Organ Effective Modulation

Safer care for patients and providers by limiting dose to radio sensitive organs and during fluoro procedures.

  • Reducing radiation exposure at specific tube angles
  • Reducing dose to radiosensitive organs and making CT safer for routine diagnostic exams
  • Reducing dose to physician during a biopsy procedure
  • Reducing dose to radio sensitive organs by switching off radiation on anterior anatomy during a biopsy procedures

Image Guided Treatment Delivery | Ultrasound

Intuitive and Innovative image guidance for precise procedures.

Aplio i-series

Canon Medical Systems' flagship ultrasound system, the Aplio i-series system, is designed to deliver outstanding clinical precision and departmental productivity. Crystal-clear images with enhanced resolution and penetration as well as an abundance of expert tools help you image with precision for biopsies and treatment delivery guidance.

Aplio i-series

Biopsy Enhancement Auto Mode (BEAM)

Enhances visualization of the needle during linear transducer biopsies.

One-button needle enhancement designed to help minimize complications and increase accuracy during interventional procedures.

  • Standard on most linear transducers
  • No sacrifice in image quality

Available on all current systems

Biopsy Enhancement Auto Mode (BEAM)

Smart Navigation

Canon Medical Systems' Smart Navigation technology is designed to help improve confidence during ultrasound-guided interventional procedures.

  • Displays virtual biopsy lines corresponding with the needle positions on the fused live image to facilitate navigation
  • Improves visualization of needle tip for up to 3 biopsy needles
  • Used in conjunction with CIVCO's virtuTRAX for Aplio 500 Platinum and omniTRAX on i-series
Smart Navigation
  • Needle out of the near side of the scan plane (non-name plate side of the probe)
  • Needle out of the plane on the far side of the scan plane (name plate side of the probe)
  • Needle line in the plane
  • Position of the needle tip
  • Crossing point of the navigation line and the live ultrasound image

Smart Fusion Technology*

Simplify your workflow with Smart Fusion

Smart Fusion* offers the best of both worlds by synchronizing ultrasound with CT or MR images to help locate hard-to-find lesions and improving confidence during ultrasound-guided biopsies. Smart Fusion reads CT/MR/US DICOM data sets using position sensors located on the ultrasound transducer, displays the corresponding images, side-by-side with the live ultrasound image. Smart Fusion can help you prioritize safety and radiation dose during interventional procedures.


*Available on Aplio 500 Platinum and i-series

Smart Fusion Technology
Merging modalities to improve confidence

Merging modalities to improve confidence

Matching the transducer position with the pre-acquired 3D data set is a simple and quick two-step process. By moving the transducer over the region of interest you can now browse the area simultaneously in both real-time ultrasound and pre-acquired volume data. Intelligent target and marker points facilitate navigation in the region of interest.

Prostate Fusion Biopsy

Fusion Ovary

Fusion Ovary

1 Toyoda H., et .al., Impact of a Unified CT Angiography System on Outcome of Patients with Hepatocellular Carcinoma, American Journal of Roentgenology, 2009;192:766-774.
2 Gogna, A., Angio CT for miscellaneous cases: complex RFA, drainages, IR 2013. Angio CT Studies Update.
3 Hiong, T. K., Angio CT for SIRT, IR 2013. Angio CT Studies Update.
4 Tanaka T, Arai Y, Inaba Y, Inoue M, Nishiofuku H, Anai H, et al. Current role of hybrid CT/angiography system compared with C-arm cone beam CT for interventional oncology. Br J Radiol 2014;87:20140126.

pt >