Get streamlined workflow, high-quality images and maximum patient comfort in Canon Medical Systems' Vantage Galan 3T MR system. The system was designed to meet the needs of you and your patients, giving you the tools you need to provide better patient care without compromising the patient experience.
Canon’s Advanced intelligent Clear-IQ Engine (AiCE) Deep Learning Reconstruction (DLR) removes inherent noise which helps you to alleviate the fundamental tradeoff between SNR, resolution and scan time. AiCE allows high SNR1 orthopedic imaging with short scan times.
Courtesy of Canon Medical Systems USA
View Scan ParametersImaging Technique | TR/TE | FOV | Resolution | Slice Thickness | Time | Canon Technology | Canon Tech |
---|---|---|---|---|---|---|---|
Axial PD FSE | 2203ms/22ms | 12cm x 14cm | 0.2 x 0.2 | 3.0mm | 0:36 | SPEEDER, T2+ AiCE |
|
Axial PD FSE Fat Sat | 2500ms/22ms | 12cm x 14cm | 0.2 x 0.2 | 3.0mm | 0:40 | SPEEDER, FS-Lite, T2+ AiCE |
|
Coronal T1 FSE | 535ms/10ms | 12cm x 14cm | 0.2 x 0.2 | 3.0mm | 0:38 | SPEEDER, T2+ AiCE |
|
Sag PD FSE | 1250ms/30ms | 14cm x 14cm | 0.2 x 0.2 | 3.0mm | 0:38 | SPEEDER, T2+ AiCE |
|
Sagittal T2 FSE Fat Sat | 2508ms/66.5ms | 14cm x 14cm | 0.2 x 0.2 | 3.0mm | 0:38 | SPEEDER, FS-Lite, T2+ AiCE |
*Actual Scan times may vary by case
1 AiCE provides higher SNR compared to typical low-pass filters
2 Actual scan time reductions vary by case
Canon’s Advanced intelligent Clear-IQ Engine (AiCE) Deep Learning Reconstruction (DLR) removes inherent noise which helps you to alleviate the fundamental tradeoff between SNR, resolution and scan time. AiCE allows high SNR1 orthopedic imaging with short scan times.
Courtesy of Canon Medical Systems USA
View Scan ParametersImaging Technique | TR/TE | FOV | Resolution | Slice Thickness | Time | Canon Technology | Canon Tech |
---|---|---|---|---|---|---|---|
Axial PD FSE FatSat | 2700ms/22ms | 14cm x 14cm | 0.2 x 0.2 | 2.5mm | 0:54 | SPEEDER, FS-Strong, T2+ | |
Sagittal PD FSE | 1900ms/30ms | 14cm x 14cm | 0.2 x 0.2 | 2.5mm | 0:58 | Compressed SPEEDER, T2+ | |
Sagittal T2 FSE Fat Sat | 3800ms/66.5ms | 14cm x 14cm | 0.2 x 0.2 | 2.5mm | 0:57 | Compressed SPEEDER, FS-Strong, T2+ | |
Coronal T1 FSE | 500ms/10ms | 14cm x 14cm | 0.2 x 0.2 | 2.5mm | 0:58 | SPEEDER, T2+ | |
Coronal PD FSE Fat Sat | 2900ms/28.5 | 14cm x 14cm | 0.2 x 0.2 | 2.5mm | 0:58 | SPEEDER, FS-Strong, T2+ |
*Actual Scan times may vary by case
1 AiCE provides higher SNR compared to typical low-pass filters
2 Actual scan time reductions vary by case
Canon’s Advanced intelligent Clear-IQ Engine (AiCE) Deep Learning Reconstruction (DLR) removes inherent noise which helps you to alleviate the fundamental tradeoff between SNR, resolution and scan time. AiCE allows high SNR1 orthopedic imaging with short scan times.
Courtesy of Canon Medical Systems USA
View Scan ParametersImaging Technique | TR/TE | FOV | Resolution | Slice Thickness | Time | Canon Technology | Canon Tech |
---|---|---|---|---|---|---|---|
Axial T2 FSE FatSat | 2500ms/60ms | 14cm x 14cm | 0.2 x 0.2 | 3.0mm | 1:33 | SPEEDER, FS-Strong, T2+ AiCE |
|
Coronal PD FSE | 1834ms/40ms | 14cm x 14cm | 0.2 x 0.2 | 3.0mm | 0:58 | Exsper, T2+ AiCE |
|
Coronal PD FSE Fat Sat | 2600ms/44ms | 14cm x 14cm | 0.3 x 0.3 | 3.0mm | 0:57 | SPEEDER, FS-Strong, T2+ AiCE |
|
Sagittal PD FSE | 1400ms/33ms | 14cm x 14cm | 0.2 x 0.2 | 3.0mm | 0:58 | SPEEDER, T2+ AiCE |
|
Sagittal PD FSE Fat Sat | 1500ms/44ms | 14cm x 14cm | 0.2 x 0.2 | 3.0mm | 0:58 | SPEEDER, FS-Strong, T2+ AiCE |
*Actual Scan times may vary by case
1 AiCE provides higher SNR compared to typical low-pass filters