53-year-old female patient presented with sudden onset of shortness of breath, dull chest pain, elevated D-dimer test, normal ECG and cardiac enzymes immediately post international air travel. After clinical evaluation and patient history review, the patient was referred to undergo a Pulmonary CT Angiography.
Pulmonary CT Angiography successfully ruled out pulmonary embolism. When evaluating for suspected pulmonary embolism, fast acquisition times and intravenous contrast optimization are critical for immediate and accurate diagnosis as pulmonary embolism can be life-threatening, prompt treatment is paramount.
Ultra-Helical (160 detector row acquisition), Active Collimation, AIDR, XYZ Modulation. Developed exclusively by Canon Medical Systems, Ultra-Helical scanning with Active Collimation facilitates a faster diagnosis by performing high-quality exams using the industry's only 8 cm z-axis coverage per rotation, 0.5 x 160 detector row acquisition.
The ability to visualize the pulmonary arteries while insuring a low patient dose was made possible with the use of Ultra-Helical scan mode, Active Collimation and AIDR. Additionally, intravenous contrast amount was decreased to just 50 ml as a result of the fast 2.3 second scan time.
AIDR has been developed as the next step in the evolution of noise reduction technology.
AIDR is an iterative algorithm where noise is removed from the original data, the results are analyzed and the process is repeated until the target level of noise reduction is achieved. This iterative algorithm is superior in removing background noise while preserving diagnostic information compared to non-iterative approaches. AIDR can be applied to all acquisition modes for routine clinical use and is able to remove image noise resulting in dose reduction.
Ultra-Helical scanning can provide whole body coverage with ultra fast scan times.
Developed exclusively by Canon Medical Systems, Ultra-Helical scanning with Active Collimation facilitates a faster diagnosis by performing ultrafast, high-quality exams using the industry's only 8 cm, 0.5 mm x 160 detector row acquisition. Able to perform scanning without any field-of-view (FOV) limitation, Ultra-Helical is ideal for trauma and whole body CTA acquisition. It can also optimize IV contrast usage resulting in shorter studies and greater patient safety.
In Helical scanning, exposure is needed before the start and after the end of the planned scan range in order to reconstruct images at these positions. This over-ranging requires at least one extra rotation, although only a small portion of this data is utilized. Active Collimation synchronizes the width of the X-ray beam at the ends of the scan range to the clinically useful area needed for image reconstruction. By eliminating exposure that is not used for diagnosis, patient dose can be reduced.
Active Collimation can reduce patient dose by eliminating exposure associated with over-ranging.
*In clinical practice, the use of the AIDR feature may reduce CT patient dose depending on the clinical task, patient size, anatomical location and clinical practice. A consultation with a radiologist and a physicist should be made to determine the appropriate dose to obtain diagnostic image quality for the particular clinical task.