Please ensure Javascript is enabled for purposes of website accessibility INSTINX, AI-Assisted Workflow Automation | AI Workflow Automation | Computed Tomography – CT Scanners | Canon Medical Systems USA
INSTINX Workflow Automation

Enhancing Efficiency through Autonomous CT

INSTINX*, AI-Assisted Workflow Automation

Intuitive operation and intelligent automated workflows provide quick scan planning and more consistency between operators regardless of their experience while contributing to work satisfaction, time savings and flexible allocation of resources.

* Depending on system configuration.

INSTINX*, AI-Assisted Workflow Automation

Optimized and consistent imaging that drives workflow and efficiency.

INSTINX, AI-Assisted Workflow Automation: Easy to learn operations infographic

* Depending on system configuration.
1 Based on a study performed at Hakujyuji Hospital, Japan with 40 cases, 10 technologists comparing manual scan planning on Aquilion ONE with automatic scan planning on Serve for body examinations.
2 Based on an ALD evaluation of 240 3D Landmark scans (40 Head, 200 Body) 3D landmark scan data. Cases in which the relevant anatomic landmark(s) were not present (9) were excluded. 97% accuracy is based on results within +/- 1 cm of target start, end, and FOV position, confirmed by two experienced CT Technologists.

INSTINX**, AI-Assisted Workflow Automation

Intuitive operation and intelligent automated workflows.

INSTINX, AI-Assisted Workflow Automation Infographic

Quick Patient Positioning

Intuitive, AI-Assisted Scanning

Consistent, High-Quality Results

* Option
** Depending on system configuration.
1 ALD - Anatomical Landmark Detection.
2 Auto SURESubtraction Iodine Mapping and Bone Removal.
3 Based on an ALD evaluation of 240 3D Landmark scans (40 Head, 200 Body) 3D landmark scan data. Cases in which the relevant anatomic landmark(s) were not present (9) were excluded. 97% accuracy is based on results within +/- 1cm of target start, end, and FOV position, confirmed by two experienced CT Technologists.

Enhancing Efficiency through Autonomous CT

INSTINX*, AI-Assisted Workflow Automation.

  • Intuitive operation and intelligent automated workflows
  • Simple and accurate scan planning
  • Consistency between operators regardless of their experience
INSTINX Infographic

* Depending on system configuration.
1 Based on a study performed at Hakujyuji Hospital, Japan with 40 cases, 10 technologists comparing manual scan planning on Aquilion ONE with automatic scan planning on Serve for body examinations.
2 Based on an ALD evaluation of 240 3D Landmark scans (40 Head, 200 Body) 3D landmark scan data. Cases in which the relevant anatomic landmark(s) were not present (9) were excluded. 97% accuracy is based on results within +/- 1 cm of target start, end, and FOV position, confirmed by two experienced CT Technologists.
3 SURESubtraction Iodine Mapping and Bone Removal.

Elevating the Operator Experience

INSTINX*, AI-Assisted Workflow Automation

Easy to learn operating system (UX) for the new generation of Canon CT systems. Optimizing workflow from referral to reporting while improving consistency and efficiency.

Featuring:

  • AI-assisted, intuitive, efficient, faster patient throughput
  • Streamlined experience
  • Save time and improve consistency
  • 3D Landmark Scan and Anatomical Landmark Detection (ALD) technology
  • Compact scan control system with 27-inch 4K monitor
Operating System Comparison

Current User Experience

Enhanced User Experience

* Depending on system configuration.

3D Landmark Scan with INSTINX*

Automatic scan planning with 3D data at doses of 2D Scanogram.

Improve confidence, accuracy and consistency for scan planning with the industry's first, 3D Landmark Scan that is dose neutral with SIlverBeam1.

* Depending on system configuration.
1 Compared to 2D Scanogram
2 3D Landmark can be used for CT contrast bolus tracking without the need for an additional scan to confirm the region of interest.

Anatomical Landmark Detection (ALD) with INSTINX1

AI-trained, reliable and consistent automated scan planning.

Take the guesswork out and simplify scan planning, save time, and achieve consistent, high-quality results with Canon’s AI-trained Anatomical Landmark Detection (ALD).

This technology enabled by the 3D Landmark Scan, has been trained to accurately identify landmarks within each patient to match the anatomical scan range set in the protocol ensuring consistency among technologists2.

Conventional Protocol Scan vs INSTINX Automated Workflow

1 Depending on system configuration.
2 Based on a study performed at Hakujyuji Hospital, Japan with 40 cases, 10 technologists comparing manual scan planning on Aquilion ONE with automatic scan planning on Aquilion Serve for body examinations.

Customizable Hanging Layouts with INSTINX*

Easy to Navigate and Customizable Default Hanging Layouts.

Fully automated, integrated, fast image reconstructions with customized at-a-glance image series review on the CT operator console before moving the patient from the CT table.

* Depending on system configuration.